QLFM-Qseries isolated phase busbar is used as the main transmission circuitconnection between the generator outgoing line and main transformer to transmitthe electricity safely. This product conforms to the IEEE C37.23, GB/T 8349 andother standards at home and abroad. The forced air cooled isolated bus ductadopts the cooling air to force the conductor and the enclosure cooled, whichcooling air is located in the closed circulation system. When the air of busduct is heated, it will go into the air-water heat exchanger, and then go backto the bus duct through the fan after cooling. The water and air could berecycled. The circulating water of power plant could be used as the cooledwater of heat exchanger to cool the air.

ProductFeatures

1. Adopt the forced air cooling device and minimize the size of the bus duct to reduce thesite installation workload and save the site space.

2. The application of one-work-one-standby fan and heat exchanger can ensure thelong-term and reliable operation.

3. To improvethe product safety performance, the monitoring and alarm module is integratedto show the temperature, humidity, wind pressure and water pressure, other keyoperation parameters.

4. Adoptingthe simulation calculation to ensure the bus duct can run 120 minutes safelyafter the failure of the forced air cooling device.

5. Theenclosure protection class can reach IP65 to prevent the human body and outsideparticles from approaching the electrified body to ensure the personal safetyand reliable operation of equipment.

Why buyers in this range contact us

  • 34 machines across 7 product groups in Electric Equipment
  • Export packing, documentation and shipping arranged from Shanghai
  • All inquiries answered within 24 hours, by email, WhatsApp or Skype
Detailed specifications are available on request.
Capacity, chassis, engine and attachment configuration vary by build. Send us your requirement and we will return the manufacturer datasheet for the configuration quoted.

↔ Swipe the table sideways to see all columns.

Reserved specification fields

Data supplied by the manufacturer on request.
ModelBusbar
Product typeBus-bar
CategoryElectric Equipment › Bus-bar
Rated capacity / outputOn request
ConfigurationOn request
Engine & emission standardOn request
Overall dimensionsOn request
WeightOn request

Specifications are reproduced from the manufacturer's published data for this model; final configuration is confirmed on the quotation.

Looking for a different capacity or configuration?

Tell us the model, the working condition or the destination port — we will confirm availability and price within 24 hours.